My contact person
igus® do Brasil Ltda

Av. Marginal Norte da Rodovia Anhanguera

Nº 53780 - Vila Rami

13206-245 – Jundiaí-SP

Fon +55 11 3531 4487

Fax +55 11 3531 4488

Harnessed cables according to manufacturer standard readycable®

Ready-to-connect cables for energy chains according to 24 manufacturer standards.
readycable® harnessed cables in accordance with manufacturer standards are drive cables specially designed for a long service life in moving applications in energy chains, fail-safe with a 36-month guarantee. They are based on the proven chainflex® cables from igus® and are tested with many millions of cycles in real applications in the igus® test laboratory.
More than 4,000 harnessed cables such as motor cables, servo cables, signal cables and encoder cables in accordance with 24 manufacturer standards, certified by and in conformity with, e.g. UL, CSA, CE or Desina, are available to choose from. readycable® harnessed drive cables can be supplied in the exact length without any cutting charges or surcharges for small quantities.

Gama

Filtrar

Requisitos do condutor
Material
Requirements

Quantidade de produtos: 122

readycable® brake cable acc. to Fanuc standard LX660-8077-T311, base cable iguPUR 12.5 x d
  • Requirements: For flexing applications 
  • Outer jacket: iguPUR 
  • Overall shield
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • chainflex® class: 3.1.3.1 

de 100,46 USD / Pc.

Ir à página do produto
readycable® brake cable acc. to Fanuc standard LX660-8077-T311, base cable PUR 6.8 x d
  • Requirements: For heavy duty applications 
  • Outer jacket: PUR 
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • chainflex® class: 5.5.3.1 

de 100,73 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T259, base cable iguPUR 15 x d
  • Requirements: For flexing applications 
  • Outer jacket: iguPUR 
  • Overall shield
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • chainflex® class: 3.1.3.1 

de 135,78 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T261, base cable iguPUR 15 x d
  • Requirements: For flexing applications 
  • Outer jacket: iguPUR 
  • Overall shield
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • chainflex® class: 3.1.3.1 

de 249,38 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T261, base cable PUR 7.5 x d
  • Requirements: For extremely heavy duty applications 
  • Outer jacket: PUR 
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Halogen-free
  • Silicone-free
  • Flame retardant
  • Offshore
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Notch-resistant
  • PVC-free
  • CFRIP®
  • chainflex® class: 6.5.3.1 

de 303,31 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T261, base cable PUR 10 x d
  • Requirements: For medium duty applications 
  • Outer jacket: PUR 
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Halogen-free
  • Silicone-free
  • Flame retardant
  • Offshore
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Notch-resistant
  • PVC-free
  • chainflex® class: 4.2.3.1 

de 302,85 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T261, base cable PVC 7.5 x d
  • Requirements: For heavy duty applications 
  • Outer jacket: PVC 
  • Overall shield
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-4-1 
  • chainflex® class: 5.5.2.1 

de 302,80 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T261, base cable PVC 15 x d
  • Requirements: For flexing applications 
  • Outer jacket: PVC 
  • Overall shield
  • Flame retardant
  • Silicone-free
  • Oil resistance: No oil resistance 
  • chainflex® class: 3.1.1.1 

de 302,88 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T261, base cable TPE 7.5 x d
  • Requirements: For extremely heavy duty applications 
  • Outer jacket: TPE 
  • Overall shield
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Silicone-free
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organc oils according to VDMA 24568 with Plantocut 8 S-MB by DEA 
  • chainflex® class: 6.6.4.1 

de 303,05 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T264, base cable iguPUR 15 x d
  • Requirements: For flexing applications 
  • Outer jacket: iguPUR 
  • Overall shield
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • chainflex® class: 3.1.3.1 

de 181,67 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T264, base cable PUR 7.5 x d
  • Requirements: For extremely heavy duty applications 
  • Outer jacket: PUR 
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Halogen-free
  • Silicone-free
  • Flame retardant
  • Offshore
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Notch-resistant
  • PVC-free
  • CFRIP®
  • chainflex® class: 6.5.3.1 

de 404,94 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T264, base cable PUR 10 x d
  • Requirements: For medium duty applications 
  • Outer jacket: PUR 
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Halogen-free
  • Silicone-free
  • Flame retardant
  • Offshore
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Notch-resistant
  • PVC-free
  • chainflex® class: 4.2.3.1 

de 404,26 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T264, base cable PVC 7.5 x d
  • Requirements: For heavy duty applications 
  • Outer jacket: PVC 
  • Overall shield
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-4-1 
  • chainflex® class: 5.5.2.1 

de 404,09 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T264, base cable PVC 15 x d
  • Requirements: For flexing applications 
  • Outer jacket: PVC 
  • Overall shield
  • Flame retardant
  • Silicone-free
  • Oil resistance: No oil resistance 
  • chainflex® class: 3.1.1.1 

de 403,32 USD / Pc.

Ir à página do produto
readycable® power cable acc. to Fanuc standard LX660-8077-T264, base cable TPE 7.5 x d
  • Requirements: For extremely heavy duty applications 
  • Outer jacket: TPE 
  • Overall shield
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Silicone-free
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organc oils according to VDMA 24568 with Plantocut 8 S-MB by DEA 
  • chainflex® class: 6.6.4.1 

de 404,68 USD / Pc.

Ir à página do produto

Consulta

Envio e consulta

Pessoalmente:

De segunda à quinta das 8:00 - 17:00

Online:

24h